The 'EXPANSION' connector on the rear of LabSat 3 gives access to a number of signals including CAN Bus, RS232, 1PPS and Digital input/output. Accessory RLACS202 is used to provide user signal access for integration into the users test system.
Number
Name
I/O
Function
1
1PPS
O
Signal from Internal GNSS monitor. Becomes active when monitor is locked. 5 V Level. 25 mA
2
DIGO
O
User digital output. 5 V Level. 25 mA max
3
DIGI
I
User digital input. Up to 12 V input level. Detection threshold=2.5 V
4
-
-
-
5
-
-
-
6
-
-
-
7
-
-
-
8
-
-
-
9
-
-
-
10
CAN 1 H
I/O
CAN Bus High Channel 1 – Standard ISO 11898 voltage signal levels for CAN
11
CAN 1 L
I/O
CAN Bus Low Channel 1 – Standard ISO 11898 voltage signal levels for CAN
12
CAN 2 H
I/O
CAN Bus High Channel 2 – Standard ISO 11898 voltage signal levels for CAN
13
CAN 2 L
I/O
CAN Bus Low Channel 2 – Standard ISO 11898 voltage signal levels for CAN
14
I2C SDA
I/O
I2C Bus Data – Reserved for future use
15
I2C SCL
I/O
I2C Bus Data – Reserved for future use
16
I2C VCC
I/O
I2C Bus Data – Reserved for future use
17
RS232 Tx
O
RS232 data output. NMEA Data from GNSS monitor or User RS232 data if enabled. Standard RS232 Level
18
RS232 Rx
I
User RS232 data which is recorded if RS232 is enabled in Digital configuration menu. Standard RS232 Level
19
Ground
O
Ground Connection
20
Ground
O
Ground Connection
21
Ground
O
Ground Connection
22
-
-
-
23
-
-
-
24
-
-
-
25
-
-
-
26
-
-
-
27
-
-
-
28
IO_0
I/O
Reserved
29
IO_1
I/O
Reserved
30
IO_2
I/O
Reserved
31
IO_3
I/O
Reserved
32
-
-
-
33
Ground
O
Ground Connection
34
Ground
O
Ground Connection
35
Power
O
Connected to input power – Max 250 mA
36
Power
O
Connected to input power – Max 250 mA
Expansion Connector (RLACS202)
Locking Expansion Connector (RLACS261)
Connector 1 - RS232 (9-PIN SUB-D)
PIN
I/O
Function
Range
2
O
Tx
RS232 data output. NMEA Data from GNSS monitor or User RS232 data if enabled. Standard RS232 Level
3
I
Rx
User RS232 data which is recorded if RS232 is enabled in Digital configuration menu. Standard RS232 Level
5
O
Ground
-
Connectors 2 / 3 - CAN 1 / CAN 2 (9 PIN SUB-D)
PIN
I/O
Function
Range
2
I/O
CAN Low
CAN Bus Low Channel 1/2 – Standard ISO 11898 voltage signal levels for CAN
7
I/O
CAN High
CAN Bus High Channel 1/2 – Standard ISO 11898 voltage signal levels for CAN
We use cookies to ensure the Support Centre functions correctly and to understand how it is used so we can improve it.
We use analytics tools, including Google Analytics, which require your consent.
You can accept or reject analytics cookies. Essential cookies are always enabled.